Product Details:
Operation supply voltage range | 2.6 ~ 5.5V |
Current consumption including on-chip analog power supply regulator | normal operation < 1.5mA, power down <1uA |
Simultaneous | 50 and 60Hz supply rejection |
Size | 40mmx20mm/1.56"x0.79"(inch) (approx) |
Selectable | 10SPS or 80SPS output data rate |
Simple digital control and serial interface | pin-driven controls, no programming needed |
Product Details:
Media | Liquid |
Material | Copper |
Model | SEN-HZG1WA |
Use voltage | DC 5V. |
Connect way | G1",60*34*34(mm). |
Working voltage range | DC 4.5 to 18V |
Max. Working current | 15mA. |
Test range | 4 to 45L/min |
Product Details:
Cable Length | 30 CM |
Holding/ Suction Force | 60 KG |
Operating Voltage | 24 VDC |
Max. Operating Current | 670 mA |
Power Consumption | 15 W |
Operating Temperature Range | 40 TO 130 C |
Product Details:
Model Name/Number | DC 12V KK-P30/25 |
Holding/ Suction Force | 15 KG |
Operating Voltage | 12 VDC |
Max. Operating Current | 300 mA |
Power Consumption | 3 W |
Operating Temperature Range | 20 TO 120 C |
Product Details:
Cable Length | 30 CM |
Holding/ Suction Force | 30 KG |
Operating Voltage | 24 VDC |
Max. Operating Current | 340 mA |
Power Consumption | 7.5 W |
Operating Temperature Range | 25 TO 105 C |
Product Details:
Size | 34mm x 34mm |
The use of four full-bridge sensors measuring range is the range of four sensors and | 50kgx4 = 200kg |
The use of only two full-bridge sensors measuring range is the range of the two sensors and | 50kgx2 = 100kg |
Using a sensor with external resistors full bridge measurement range of a sensor range | 50kg. Higher requirements for external resistor |
i.e., a strain gauge affixed to the middle | with a beam of white plastic cover arm |
outside edges to form a shear force in the opposite direction | i.e., in the middle of strain beam bending necessary changes can occur under stress, strain beam sid |
Product Details:
Flow Range | 5-150L/min; |
working voltage | DC4.5-12V; |
rated voltage | 5 VDC |
Output voltage(rated: DC 5V) | High level 4.5V and above; low level 0.5V and below |
Pulse output duty cycle | 50+-10% |
Insulation resistance | 100M Ohm and above; |
Product Details:
Load Capacity | 10 mA DC 5V |
Temperature | 80 C |
Allowed pressure | pressure 1 75Mpa |
Operating humidity range | 35 90 RH no frost |
Working voltage range | DC 5 18V |
Maximum operating current | 15 mA DC 5V |
Product Details:
Capacity | 10 Kg |
Rated Output | 0.1-1 mV / V |
Dimensions | 75x12.7x8 mm |
Model | YZC-131A |
Nonlinear | 0.05% F.S |
Additional Information:
Product Details:
Lifting Capacity | 5KG |
Operating Voltage | 12V DC. |
Size | (D x L): 25 x 20 mm. |
Electric lifting magnet. | Powerful and compact. |
Smooth and flat surface. | Low consumption and reliable. |
Ambient temperature within | 130 degrees. |